Beware that this venue data has not been confirmed for more than a year

Venuekeyboard_arrow_up

Venue or place namePalais Nikaïa
Room nameNIKAÏA LIVE
CityNICE
Postal code06200
Address163, Route de Grenoble
Google map link
Phone+334 92 29 31 28
Websitehttp://www.nikaia.fr/
Technical info pagehttp://www.nikaia.fr/medias/File/fiche-technique-nikaia-12-10-11.pdf
Virtual visit

Technicians Contactskeyboard_arrow_down

Technical Director / Manager NameJean-Pierre MARQUET
Phone+334 92 29 31 28
Emailjmarquet@nikaia.fr
Names of other technical contactsregie.technique@nikaia.fr

Accesskeyboard_arrow_down

Truck
Address / unloading dock info, freight elevator (size) (English)Deux portes d’accès camion dans la salle, à cour et jardin, de 5,40m de largeur sur 4,30m de hauteur
Bus Tour
Power plugs available for the bus:
CEE P17 32A1
PC 16A4
Artists

Power Availablekeyboard_arrow_down

Electrical cabinet 1
Sound/Light/Video/Accessory Name Number Total power Transformer Position (stage) Position Distance to stage
LUMIERE
Connector Qty Phases Amp Diff Notes
CEE P17 63A 2 Tetra
CEE P17 32A 1 Tetra
CEE P17 16A 1 Tetra
Other 2 Mono 16 PC16
Electrical cabinet 2
Sound/Light/Video/Accessory Name Number Total power Transformer Position (stage) Position Distance to stage
LUMIERE
Connector Qty Phases Amp Diff Notes
CEE P17 63A 1 Tetra
CEE P17 32A 2 Tetra
Other 4 Mono 16 PC16
CEE P17 32A 2 Mono BLEU

Room / Gaugeskeyboard_arrow_down

Configurations
Configuration name Seating places Standing room PRM Total
350 900 1250

Stagekeyboard_arrow_down

Lightkeyboard_arrow_down

Grill plot

Dressing room, Office, Cateringkeyboard_arrow_down

Dressing rooms
Production office
Catering
How many plugs:
Utility room
If the room is empty:

Official Documents

Description Added
DOSSIER TECHNIQUE 2015 2020-04-11
Soundvision 2020-04-11